Grasshopper

algorithmic modeling for Rhino

00 | Honeybee
01 | Daylight | Material
02 | Daylight | Light Source
03 | Daylight | Recipes
04 | Daylight | Daylight
05 | Energy | Building Program
06 | Energy | Material | Construction
07 | Energy | Schedule
08 | Energy | Set Zone Properties
09 | Energy | HVACSystems
10 | Energy | Energy
11 | THERM
12 | Developers
13 | WIP

Read Annual Result I

Component Index > Honeybee > 04 | Daylight | Daylight > Read Annual Result I

Read Annual Daylight Results I [Standard Daysim Results]

Inputs

NameIDDescriptionType
_illFilesAddress_illFilesAddressList of .ill filesGoo
_testPoints_testPointsList of 3d PointsGoo
ptsVectors_ptsVectors_Script variable readDSResultsGoo
occupancyFiles_occupancyFiles_Address to a Daysim occupancy file. You can find some example in \Daysim\occ. Use Honeybee Occupancy Generator to generate a custom occupancy file. You can also use EnergyPlus Schedules directly. If the schedule is using continuous values any value larger than .2 will be considered as occupied.Goo
_DLAIllumThresholds__DLAIllumThresholds_Illuminance threshold for Daylight Autonomy calculation in lux. Default is set to 300 lux.Goo
lightingControlGroups_lightingControlGroups_Daysim lighting control groups. Daysim can model up to 10 lighting control groups together. Default is > cntrlType = 4, lightingPower = 250, lightingSetpoint = 300, ballastLossFactor = 20, standbyPower = 3, delayTime = 5Goo
SHDGroupI_Sensors_SHDGroupI_Sensors_Senors for dhading group I. Use shadingGroupSensors component to prepare the inputsGoo
SHDGroupII_Sensors_SHDGroupII_Sensors_Senors for dhading group II. Use shadingGroupSensors component to prepare the inputsGoo
_runIt_runItset to True to run the analysisGoo

Outputs

NameIDDescriptionType
DLADLADaylight Autonomy > Percentage of the time during the active occupancy hours that the test point receives more daylight than the illuminance threshold.Goo
UDLI_Less_100UDLI_Less_100Useful Daylight illuminance > Percentage of time during the active occupancy hours that the test point receives less than 100 lux.Goo
UDLI_100_2000UDLI_100_2000Useful Daylight illuminance > Percentage of time during the active occupancy hours that the test point receives between 100 and 2000 lux.Goo
UDLI_More_2000UDLI_More_2000Useful Daylight illuminance > Percentage of time during the active occupancy hours that the test point receives more than 2000 lux.Goo
CDACDAContinuous Daylight Autonomy > Similar to Daylight Autonomy except that the point receives illuminaceLevel/illuminace threshold for hours that illuminance level is less than the threshold.Goo
sDAsDASpatial Daylight Autonomy > sDA is the percent of analysis points across the analysis area that meet or exceed _DLAIllumThresholds value (set to 300 lux for LEED) for at least 50% of the analysis period. Honeybee doesn't consider the effect of dynamic blinds in calculating sDA.Goo
annualProfilesannualProfilesA .csv file generated by Daysim that can be used as lighting schedule for annual energy simulationGoo
htmReporthtmReportScript variable readDSResultsGoo

© 2018   Created by Robin Rodricks and Andrew Heumann.   Hosted by

Badges  |  Report an Issue  |  Terms of Service