Grasshopper

algorithmic modeling for Rhino

0 | Ladybug
1 | AnalyzeWeatherData
2 | VisualizeWeatherData
3 | EnvironmentalAnalysis
4 | Renewables
5 | Extra
6 | Developers
7 | WIP

Cold Water Temperature

Component Index > Ladybug > 4 | Renewables > Cold Water Temperature

Use this component to calculate the cold (inlet, mains) water temperature, if water pipes are burried undeground.
Sources:
http://www.energy.ca.gov/2013publications/CEC-400-2013-003/CEC-400-2013-003-CMF-REV.pdf
http://www.nrel.gov/docs/fy04osti/35917.pdf
http://www.solarthermalworld.org/sites/gstec/files/story/2015-05-31/textbook_swh.pdf

Inputs

NameIDDescriptionType
method_method_A method by which the cold water temperature will be calculated: - 0 - Carslaw and Jaeger (used by DOE-2) 1 - Christensen and Burch (used by EnergyPlus) 2 - used by RETScreen - If not supplied, method "1" (Christensen and Burch) will be used by default.Goo
_dryBulbTemperature_dryBulbTemperatureHourly Dry Bulb Temperature (air temperature). Import it from Ladybug "Import EPW" component. - In °C.Goo
minimalTemperature_minimalTemperature_The minimum cold temperature value. For example this input can be used to prevent the water in your pipes from freezing, by limiting it to 1°C (33.8F). - If not supplied, default value 1 (°C) will be used. - In °C.Goo
____________________________________Script variable ColdWaterTempratureGoo
soilThermalDiffusivity_soilThermalDiffusivity_The ability of a soil to conduct thermal energy relative to its ability to store thermal energy. - This input is only important for method "0" !!! Soil type for method "1" is unknown, and can not be changed. The "1" formula is derived from various field and soil data accross USA. Soil type for method "2" is fixed to: wet clay soil, and can not be changed. - Soil thermal diffusivity for particular types of soil (m2/s * 10^(-7)): 2.4 - dry sand 7.4 - wet sand 2.5 - dry clay 5.1 - wet clay 1.0 - dry peat 1.2 - wet peat 12.9 - dense rock - If not supplied, default value 2.5 (dry clay) will be used. - In m2/s * 10^(-7).Goo
pipesDepth_pipesDepth_The soil depth at which cold water pipes are burried at. - This input is only important for method "0" !!! Pipes depth range for method "1" is fixed from 0.3 to 1 meters (1 to 3.5 feet), and can not be changed. Pipes depth for method "2" is fixed to 2 meters, and can not be changed. - If not supplied, default value of 1(m) will be used. - In meters.Goo

Outputs

NameIDDescriptionType
outreadMe!...String
coldWaterTemperaturePerHourcoldWaterTemperaturePerHourCold water temperature for picked pipesDepth_ and soilThermalDiffusivity_, for each hour during a year. - In °C.Goo
avrJanuaryColdWaterTemperatureavrJanuaryColdWaterTemperatureAverage January cold water temperature for picked pipesDepth_ and soilThermalDiffusivity_. Use it for "SWHsystem" component's "avrJanuaryColdWaterTemperature_" input. - In °C.Goo
avrColdWaterTemperaturePerYearavrColdWaterTemperaturePerYearAverage annual cold water temperature for picked pipesDepth_ and soilThermalDiffusivity_. - In °C.Goo