Grasshopper

algorithmic modeling for Rhino

0 | Ladybug
1 | AnalyzeWeatherData
2 | VisualizeWeatherData
3 | EnvironmentalAnalysis
4 | Renewables
5 | Extra
6 | Developers
7 | WIP

Solar Water Heating Performance Metrics

Component Index > Ladybug > 4 | Renewables > Solar Water Heating Performance Metrics

Use this component to calculate various Solar water heating performance metrics.
Also use it to calculate the optimal SWH system size and tank storage volume.

Inputs

NameIDDescriptionType
_SWHsurface_SWHsurfaceUse the same "_SWHsurface" you supplied to the "Solar Water Heating Surface" component.Goo
SWHsurfacePercent_SWHsurfacePercent_The percentage of surface which will be used for SWH collectors (range 0-100). - There are no general rules or codes which would limit the percentage of the roof(surface) covered with SWH collectors. - If not supplied, default value of 100 (all surface area will be covered in SWH collectors) is used. - In percent (%).Goo
SWHsystemSettings_SWHsystemSettings_A list of all Solar water heating system settings. Use the same "SWHsystemSettings_" you supplied to the "Solar Water Heating Surface" component. - If not supplied, the following swh system settings will be used by default: - glazed flat plate collectors - active - closed loop - pipe length: 20 meters - unshadedGoo
__________________________________________________Script variable PhotovoltaicsPerformanceMetricsGoo
_heatingLoadPerHour_heatingLoadPerHourUse the same "_heatingLoadHour" you supplied to the "Solar Water Heating Surface" component. - In kWh.Goo
_heatFromTankPerHour_heatFromTankPerHourImport "heatFromTankPerHour" output data from "Solar water heating surface" component. - In kWh.Goo
_heatFromAuxiliaryHeaterPerHour_heatFromAuxiliaryHeaterPerHourImport "heatFromAuxiliaryHeaterPerHour" output data from "Solar water heating surface" component. - In kWh.Goo
_pumpEnergyPerHour_pumpEnergyPerHourImport "pumpEnergyPerHour" output data from "Solar water heating surface" component. - In kWh.Goo
__________________________________________________Script variable PhotovoltaicsPerformanceMetricsGoo
energyCostPerKWh_energyCostPerKWh_The cost of one kilowatt hour in any currency unit (dollar, euro, yuan...) - If not supplied, 0.15 $/kWh will be used as default value. - In currency/kWh.Goo
collectorEmbodiedEnergyPerM2_collectorEmbodiedEnergyPerM2_Energy necessary for product life-cycle of SWH collector per square meter. - If not supplied default value of 1135 (MJ/m2) for unglazed or glazed flat plate collector will be used. - In MJ/m2 (megajoules per square meter).Goo
tankEmbodiedEnergyPerL_tankEmbodiedEnergyPerL_Energy necessary for product life-cycle of storage tank per liter. - If not supplied default value of 20 (MJ/l) will be used. - In MJ/l (megajoules per liter).Goo
collectorEmbodiedCO2PerM2_collectorEmbodiedCO2PerM2_Carbon emissions produced during SWH collector's life-cycle per square meter.. - If not supplied default value of 65.5 (kg CO2/m2) for unglazed or glazed flat plate collector will be used. - In kg CO2/m2 (kilogram of CO2 per square meter).Goo
tankEmbodiedCO2PerL_tankEmbodiedCO2PerL_Carbon emissions produced during storage tank's life-cycle per liter. - If not supplied default value of 0.14 (kg CO2/l) for unglazed or glazed flat plate collector will be used. - In kg CO2/l (kilogram of CO2 per liter).Goo
collectorLifetime_collectorLifetime_Life expectancy of a SWH collector. - If not supplied default value of 15 (years) will be used. - In years.Goo
tankLifetime_tankLifetime_Life expectancy of a storage tank. - If not supplied default value of 10 (years) will be used. - In years.Goo
__________________________________________________Script variable PhotovoltaicsPerformanceMetricsGoo
optimal_optimal_Set to "True" to calculate optimal system size and tank storage volume. - Larger system sizes and tank volumes produce more energy, therefor cover more initial heating load, which results in less usage of auxiliary energy. However, the larger the system size and tank volume, more embodied energy is spent. In order to find an optimal system size (total size of all collectors) and storage tank volume, life-cycle energy analysis is used to acheive the maximal net energy saving of the swh system. The net energy saving of swh system is the energy saving in kWh remained after an annualized embodied energy (of collectors or storage tank) has been deducted from the operating energy saving of swh system. This method of optimization is superior in comparison with other simulation-based methods due to consideration of all energy performance stages (production, operation, maintenance...). - This optimization method can be used to account for capital costs, instead of embodied energy. This would account only for operation performance stage. In this case capital costs of collector/per square meter, and tank/per liter would need to be inputted into: "collectorEmbodiedEnergyPerM2_" and "tankEmbodiedEnergyPerL_" inputs. - Optimization analysis based on the law of diminishing marginal utility: "A simplified method for optimal design of solar water heating systems based on life-cycle energy analysis", Renewable Energy journal, Yan, Wang, Ma, Shi, Vol 74, Feb 2015 www.sciencedirect.com/science/article/pii/S0960148114004807Goo
_runIt_runIt...Goo

Outputs

NameIDDescriptionType
outreadMe!...String
optimalSystemSizeoptimalSystemSizeOptimal SWH system size (optimal total size of SWH collector's array) for a given SWHsurface's tilt, array and "_heatingLoadHour". Minimum SWH system size is 0.15 kWt. Input it to "systemSize_" input of "PV SWH system size" component to see how much area it would require. - To calculate it, set the "optimal_" input to "True". - In thermal kiloWatts (kWt).Goo
optimalTankSizeoptimalTankSizeSolar water heating storage tank optimal size (volume). Minimum size is 100 liters. To calculate it, set the "optimal_" input to "True". - In liters.Goo
__________________________________Script variable SWHperformanceMetricsGoo
SEFSEFSolar Energy Factor - ratio of total energy provided by the swh system to auxiliary plus parasitic (circulation pump) energy for a whole year. - Unitless.Goo
SolarFractionPerMonthSolarFractionPerMonthSolar Fraction (or Solar Savings Fraction) - percentage of the heating load requirement that is provided by a swh system for each month during a year. It ranges from 0 to 100%. - In percent (%).Goo
SolarFractionPerYearSolarFractionPerYearSolar Fraction (or Solar Savings Fraction) - percentage of the total heating load requirement that is provided by a swh system for a whole year. It ranges from 0 to 100%. - In percent (%).Goo
energyValueenergyValueTotal Energy value generated by SWH system for a whole year in currency unit (dollars, euros, yuans...)Goo
EROIEROIEnergy Return On Investment - a comparison of the generated electricity to the amount of primary energy used throughout the SWH collector's product life-cycle. - Unitless.Goo
__________________________________Script variable SWHperformanceMetricsGoo
embodiedEnergyembodiedEnergyTotal energy necessary for an entire product life-cycle of SWH collectors and storage tank. - In GJ (gigajoules).Goo
embodiedCO2embodiedCO2Total carbon emissions produced during SWH collector and storage tank life-cycle. - In tCO2 (tons of CO2).Goo
CO2emissionRateCO2emissionRateAlso called Embodied GHG emissions or GHGEmissions. An index which shows how effective a SWH system is in terms of global warming. It is used in comparison with other fuels and technologies (Hydroelectricity(15), Wind(21), Nuclear(60), Geothermal power(91), Natural gas(577), Oil(893), Coal(955) ...) - In gCO2/kWh.Goo
EPBTEPBTEnergy PayBack Time - time it takes for SWH system to produce all the energy used through-out its collector's product life-cycle. - In years.Goo

© 2018   Created by Robin Rodricks and Andrew Heumann.   Hosted by